The Tool Steel Ring is a standardized test piece commonly used with wet bench magnetic particle equipment. The ring is machined from AISI O1 Tool Steel, annealed, tested and certified to meet AS 5282 specifications.
The Y-2 is an AC electromagnetic yoke, ergonomically designed to improve productivity and reduce operator arm and wrist fatigue. The yoke generates a strong AC magnetic field for the detection of surface indications during magnetic particle testing.
Lightweight with an ergonomic grip and trigger, the Y-2 is designed for the rugged demands of field inspection. Featuring a field swappable cord and isolated trigger switch; the Y-2 is easily serviceable because a severed cord should not stop a job from getting done.
A medium sensitivity penetrant (Level 2), ZL-2C fluorescent post-emulsifiable penetrant is designed to be removed from the part surface by emulsifiers or solvent.
With a UV-A light source, indications will appear as a bright green-yellow fluorescence.
ZL-2C has a high flash point, and is designed to be used in open dip tanks.
Essential for critical component applications, ultra-high sensitivity ZL-37 post-emulsifiable penetrant is designed for detecting fine, tight discontinuities in safety-critical components, such as titanium turbine components, and in high-stress parts, such as investment castings.
This Type 1 penetrant is non-water-soluble so there is minimal risk of washing ZL-37 penetrant from a fine or shallow defect which makes this penetrant inspection the most reliable, dependable form of PT testing.
ZL-37 has a high flash point and provides long tank life when used in open dip tanks, but this penetrant can also be applied in a variety of other ways, including electrostatic spray.
ZL-37 can be removed with ZE-4B Method B lipophilic emulsifier or ZR-10C Method D hydrophilic emulsifier.
Developed for testing rough machined surfaces, ZL-60C fluorescent water-removeable penetrant is ideal for finding indications in castings, forgings, extrusions and rough surfaces.
This medium-sensitivity penetrant washes off parts quickly and easily, leaving less fluorescent background – even on rough surfaces – for clearer indications and better inspection reliability. Broad specification compliance further increase this penetrants flexibility.
ZL-60C has excellent alloy compatibility and is safe to use on most engineering and aerospace materials, including aluminum, steel, nickel and titanium.
Designed to remove excess surface penetrant, ZR-10C minimizes surface background during Method D fluorescent penetrant testing while protecting indication integrity in critical component inspections.
This Method D remover reduces fluorescent background on rough surfaces and minimizes penetrant bleed-out from hollow parts. ZR-10C works with Magnaflux PE penetrants ZL-2C Level 2, ZL-27A Level 3 and ZL-37 Level 4 for verified penetrant system reliability.
ZR-10C provides long tank life and excellent solution consistency for dependable, long-lasting performance in a variety of applications.